Insulation and outer jacket made off halogen-free Polypropylene. Special heating cables, which doesn’t release any toxic or corrosive gases in the event of a fire. This prevents the rapid spread of flames.

up to 80 °C

ELSR-N-Halogenfree

low temperature

The new, self-regulating heating cable ELSR-N halogen-free closes a gap in the building technology portfolio. This halogen-free heating cable doesn't release any toxic or corrosive gases in the event of a fire. Instead, an intelligent protection principle ensures safety, as water vapour is released in the event of a fire. This cools the material, dilutes the resulting fire gases and prevents the rapid spread of flames. At the same time, a thermally stable oxide layer is formed that protects the material underneath.

Compatible accessories:

Junction Boxes: ELAK-2, ELAK-5, ELAK-5.1, ELAK-5.7, ELAK-R7, ELAK-RS, ELAK-RS-T

Technical Data

Applications

Freeze prevention

Gutters, downspouts, buildings

Water and Wastewater Systems

Technical Benefits

  • three nominal outputs
  • resistant to UV
  • moisture proof
  • halogen-free
  • flame retardant/self-extinguishing

Product Highlights

Bus wire

Nickel plated copper

Self-regulating heating element

Insulation

Halogenfreies Polypropylen

Protective conductor

Cu, tin plated

Aluminium foil

Outer jacket

Halogen-free Polypropylene

Bus wire

nickel plated copper

Self-regulating heating element

Insulation

Halogenfreies Prolypropylen

Protective braid

Cu, tin plated

Outer jacket

Halogenfreies Polypropylen

Technical Data

Bending radius, min. 25 mm
Maximum maintain temperature +65 °C
Maximum exposure temperature, de-energized +80 °C
Installation temperature, min. -60 °C
Nominal voltage 230 V

The eltherm designer

From now on, easily perform heat loss calculations for insulated and jacketed pipes and vessels yourself, or manage entire trace heating systems within your projects.

Start design
The eltherm designer

Downloads

Title
Format
Size
Language
Datenblatt ELSR-N-Halogenfrei
PDF
586 KB
Deutsch
Data sheet ELSR-N-Halogen free
PDF
583 KB
English

We are here for you

Contact persons

Gamze-Nur Akin
Gamze-Nur Akin

+49 2736 / 4413-8406

gnakin@eltherm.com

eltherm GmbH

Ernst-Heinkel-Straße 6-10
57299 Burbach, Germany
Lukas Demmer
Lukas Demmer

+49 2736 / 4413-8290

ldemmer@eltherm.com

eltherm GmbH

Ernst-Heinkel-Straße 6-10
57299 Burbach, Germany