Skip to main navigation Skip to main content Skip to page footer

Up to 700 °C

ELK-MI VA

Mineral-Insulated Clean Laser Seal Trace Heater

The ELK-MI VA heating cable is supplied by eltherm pre-assembled and ready for installation. It consists of a single- or two-wire trace heating system that is connected to mineral-insulated cold leads (copper conductors with cross-sections of 2.0, 2.5, 3.3, or 5.0 mm²) via a precise laser seal (splice).

The outer sheath is made of high-quality stainless steel 1.4541 (AISI 321). The open end of the cold conductor is seamlessly sealed and connected to a flexible supply cable whose diameter matches that of the cold conductor. Additionally, an earth connection with a conductor cross-section of 1.5 mm² is provided.

At the end of each cold lead is a pressure-resistant stainless steel compression ring fitting made of 1.4404 (AISI 316L) with an M20 × 1.5 or M25 × 1.5 thread. A molded end seal reliably protects the fitting against potential loss.

Each heating cable is supplied with a nameplate containing all relevant information and markings. The maximum holding temperatures also specified there are based on the maximum permissible jacket temperature determined by eltherm.

Compatible accessories:

Junction Boxes: ELAK-Ex 2.00, ELAK-Ex 4.21, ELAK-Ex 4.22, ELAK-Ex 4.23, ELAK-3-SP, ELAK-6-SP

Technical Data

Applications

Temperature maintenance
Pipelines
Silos, vessels, tanks

Chemical and Petrochemical Industries, Oil and Gas Industry, Industrial Processes, Mobile Processing Plants, Vacuum Processes

Technical Benefits

  • Purity: No foreign material
  • Full range of resistances
  • Fast assembly, low cost
  • 1 mile (1,6 km) on 1 circuit 
  • In by noon, out by 5
  • 100%  quality check
  • Safety: non-destructive tests
  • No filler holes. 
  • MgO = ASTM E1652. 
  • FM approved

Product Highlights

Heating conductor

Magnesium oxide (MgO) in accordance with the ASTM E1652 standard

Insulation

Magnesium oxide (MgO) in accordance with the ASTM E1652 standard

Outer jacket

Stainless steel 1.4541 (AISI 321)

Technical Data

Output, max. up to 250 W/m
Bending radius, minimal Diameter x6
Installation temperature, min. - 60 °C
Nominal voltage up to 500 V AC
Nominal temperature 700°C
IP rating IP65
Ambient temperature - 60 °C up to + 60 °C

The eltherm designer

From now on, easily perform heat loss calculations for insulated and jacketed pipes and vessels yourself, or manage entire trace heating systems within your projects.

Start design
The eltherm designer

Downloads

Title
Format
Size
Language
Datenblatt ELK-MI-VA Single
PDF
403 KB
Deutsch
Data sheet ELK-MI-VA Single
PDF
388 KB
English
Datenblatt ELK-MI-VA Twin
PDF
661 KB
Deutsch
Data sheet ELK-MI-VA Twin
PDF
647 KB
English
Broschüre ELK-MI
PDF
3 MB
Deutsch
Brochure ELK-MI
PDF
8 MB
English

We are here for you

Contact persons

Frank Vogel
Frank Vogel

+49 2736 / 4413-8158

fvogel@eltherm.com

eltherm GmbH

Ernst-Heinkel-Straße 6-10
57299 Burbach, Germany
Thomas Stuff
Thomas Stuff

+49 2736 / 4413-8155

tstuff@eltherm.com

eltherm GmbH

Ernst-Heinkel-Straße 6-10
57299 Burbach, Germany