up to 482 °F
ELKM-AG-NA
Fluoropolymer-insulated
Polymer insulated trace heating offers the most reliable and flexible means of providing freeze protection and temperature maintenance in highly corrosive environments and high temperature applications. eltherm's series ELKM-AG-NA heating cable offer unique features, including Class I Division 1 hazardous area approval.
- IBCs
- Valves, pumps
- Tank container
- Vessels and tanks
- Pipelines
- Heat tracing of intrumentation
Technical Benefits
- Class I Division 1 hazardous area rating
- Maximum chemical and mechanical resistance
- Usage rating -WS (outdoors, wet areas)
- Highly flexible, may be applied to various shapes and small spaces
- Easy field termination
- Large variety of resistances
- Longer Circuits lengths
Product highlights
Click on the red and white markers for more details.
Approvals
Technical Data
Nominal voltage (variable)
0 - 750 V AC and DC voltages
Output, max.
30 W/m
Maximum operating temperature, de-energized
482 °F / 250 °C
Bending radius, min.
0.4 in / 10 mm
Installation temperature, min.
- 76 °F / - 60 °C