up to 260 °C

ELKM-AE

Fluoropolymer-insulated with Protective Braid

Use on apparatus, vessels, pipes, valves, etc., in which low bending radii also allow compact tracing on small components across the entire surface.

  • Valves, pumps
  • Pipelines
  • Silos, vessels, tanks
  • Industrial Applications
  • IBCs
  • Antenna
Technical Benefits
  • Highly flexible
  • Small bending radius
  • High operating temperature
  • High chemical resistance
  • Moisture proof

Product highlights

Click on the red and white markers for more details.
The heating cable ELKM-AE apparatus, vessels, pipes, valves, etc.

Heating conductor:

strandet or spirally wound

Insulation:

Fluoropolymer

Protective baid:

VA 1.4401 / SS 316

  1. Heating conductor: strandet or spirally wound
  2. Insulation: Fluoropolymer
  3. Protective baid: VA 1.4401 / SS 316

Approvals

EAC

Technical Data

Protective braid
VA 1.4401 / SS 316
Nominal voltage
750 V
Output, max.
30 W/m
Nominal temperature
260 °C
Bending radius, minimal
2,5 x outer diameter
Installation temperature, min.
- 60 °C
Heat conductor
Stranded, spirally wound for nominal resistance > 8000 Ω/km